Hierarchical Protection for Smart Grids
Home > Science, Technology & Agriculture > Energy technology and engineering > Electrical engineering > Hierarchical Protection for Smart Grids
Hierarchical Protection for Smart Grids

Hierarchical Protection for Smart Grids

|
     0     
5
4
3
2
1




International Edition


About the Book

A systematic view of hierarchical protection for smart grids, with solutions to tradition protection problems and complicated operation modes of modern power systems • Systematically investigates traditional protection problems from the bird’s eye view of hierarchical protection • Focuses on multiple variable network structures and complicated operation modes • Offers comprehensive countermeasures on improving protection performance based on up-to-date research

Table of Contents:
About the Author ix Foreword xi Preface xiii Introduction xv 1 Basic Theories of Power System Relay Protection 1 1.1 Introduction 1 1.2 Function of Relay Protection 1 1.3 Basic Requirements of Relay Protection 3 1.3.1 Reliability 3 1.3.2 Selectivity 4 1.3.3 Speed 4 1.3.4 Sensitivity 5 1.4 Basic Principles of Relay Protection 6 1.4.1 Over-Current Protection 6 1.4.2 Directional Current Protection 6 1.4.3 Distance Protection 7 1.5 Hierarchical Relay Protection 9 1.5.1 Local Area Protection 10 1.5.2 Substation Area Protection 11 1.5.3 Wide Area Protection 12 1.5.4 Constitution Mode of Hierarchical Relay Protection 13 1.6 Summary 15 References 15 2 Local Area Conventional Protection 17 2.1 Introduction 17 2.2 Transformer Protection 18 2.2.1 Adaptive Scheme of Discrimination between Internal Faults and Inrush Currents of Transformer Using Mathematical Morphology 18 2.2.2 Algorithm to Discriminate Internal Fault Current and Inrush Current Utilizing Variation Feature of Fundamental Current Amplitude 30 2.2.3 Identifying Transformer Inrush Current Based on Normalized Grille Curve (NGC) 39 2.2.4 Adaptive Method to Identify CT Saturation Using Grille Fractal 50 2.2.5 Algorithm for Discrimination Between Inrush Currents and Internal Faults Based on Equivalent Instantaneous Leakage Inductance 57 2.2.6 A Two-Terminal Network-Based Method for Discrimination between Internal Faults and Inrush Currents 70 2.3 Transmission Line Protection 82 2.3.1 Line Protection Scheme for Single-Phase-to-Ground Faults Based on Voltage Phase Comparison 83 2.3.2 Adaptive Distance Protection Scheme Based on the Voltage Drop Equation 99 2.3.3 Location Method for Inter-Line and Grounded Faults of Double-Circuit Transmission Lines Based on Distributed Parameters 117 2.3.4 Adaptive Overload Identification Method Based on Complex Phasor Plane 134 2.3.5 Novel Fault Phase Selection Scheme Utilizing Fault Phase Selection Factors 148 2.4 Summary 172 References 172 3 Local Area Protection for Renewable Energy 175 3.1 Introduction 175 3.2 Fault Transient Characteristics of Renewable Energy Sources 176 3.2.1 Mathematical Model and LVRT Characteristics of DFIG 177 3.2.2 DFIG Fault Transient Characteristics When the Crowbar Protection Is Not Put into Operation 178 3.2.3 DFIG Fault Transient Characteristics When the Crowbar Protection Is Put into Operation 211 3.3 Local Area Protection for Centralized Renewable Energy 230 3.3.1 Connection Form of a Wind Farm and its Protection Configuration 231 3.3.2 Adaptive Distance Protection Scheme for Wind Farm Collector Lines 233 3.3.3 Differential Protection Scheme for Wind Farm Outgoing Transmission Line 239 3.4 Local Area Protection for Distributed Renewable Energy 248 3.4.1 Adaptive Protection Approach for Distribution Network Containing Distributed Generation 248 3.4.2 Islanding Detection Method 255 3.5 Summary 269 References 270 4 Topology Analysis 273 4.1 Introduction 273 4.2 Topology Analysis for Inner Substation 273 4.2.1 Characteristic Analysis of the Main Electrical Connection 274 4.2.2 Topology Analysis Method Based on Main Electrical Wiring Characteristics 275 4.2.3 Scheme Verification 278 4.3 Topology Analysis for Inter-substation 284 4.3.1 Static Topology Analysis for Power Network 285 4.3.2 Topology Update for Power Network 287 4.3.3 Scheme Verification 291 4.4 False Topology Identification 294 4.4.1 Road-Loop Equation 294 4.4.2 Analysis of the Impacts of Topology Error and Undesirable Data on Branch Current 296 4.4.3 Topology Error Identification Method Based on Road-loop Equation 300 4.4.4 Scheme Verification 301 4.5 Summary 315 References 316 5 Substation Area Protection 317 5.1 Introduction 317 5.2 Substation Area Protection Based on Electrical Information 317 5.2.1 Substation Area Regionalization 318 5.2.2 Typical Fault Cases 323 5.2.3 Scheme Performance Analysis 326 5.3 Substation Area Protection Based on Operating Signals 327 5.3.1 Setting Principle of Adaptive Current Protection 327 5.3.2 Supporting Degree Calculation Method 330 5.3.3 Substation Area Current Protection Algorithm 334 5.3.4 Scheme Verification 338 5.4 Summary 346 References 346 6 Wide Area Protection 347 6.1 Introduction 347 6.2 Wide Area Protection Using Electrical Information 347 6.2.1 Wide-Area Protection Using Fault Power Source Information 348 6.2.2 Wide-Area Protection Using Fault Network Information 358 6.2.3 Wide-Area Protection Suitable for Multiple Fault Identification 369 6.3 Wide Area Protection Using Operating Signals 375 6.3.1 Wide-Area Protection Based on Distance Protection Operational Signal 376 6.3.2 Wide-Area Protection Based on Current Protection Operational Signal 393 6.3.3 Wide-Area Protection Based on Virtual Impedance of Fault Component 406 6.4 Wide Area Tripping Strategy 419 6.4.1 Tripping Strategy Based on Directional Weighting 419 6.4.2 Simulation Verification 428 6.5 Summary 432 References 433 Appendices 435 Index 439


Best Sellers


Product Details
  • ISBN-13: 9781119304807
  • Publisher: John Wiley & Sons Inc
  • Binding: Hardback
  • Language: English
  • Returnable: N
  • Spine Width: 28 mm
  • Width: 170 mm
  • ISBN-10: 1119304806
  • Publisher Date: 19 Jun 2018
  • Height: 246 mm
  • No of Pages: 475
  • Returnable: N
  • Weight: 885 gr


Similar Products

Add Photo
Add Photo

Customer Reviews

REVIEWS      0     
Click Here To Be The First to Review this Product
Hierarchical Protection for Smart Grids
John Wiley & Sons Inc -
Hierarchical Protection for Smart Grids
Writing guidlines
We want to publish your review, so please:
  • keep your review on the product. Review's that defame author's character will be rejected.
  • Keep your review focused on the product.
  • Avoid writing about customer service. contact us instead if you have issue requiring immediate attention.
  • Refrain from mentioning competitors or the specific price you paid for the product.
  • Do not include any personally identifiable information, such as full names.

Hierarchical Protection for Smart Grids

Required fields are marked with *

Review Title*
Review
    Add Photo Add up to 6 photos
    Would you recommend this product to a friend?
    Tag this Book Read more
    Does your review contain spoilers?
    What type of reader best describes you?
    I agree to the terms & conditions
    You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.

    CUSTOMER RATINGS AND REVIEWS AND QUESTIONS AND ANSWERS TERMS OF USE

    These Terms of Use govern your conduct associated with the Customer Ratings and Reviews and/or Questions and Answers service offered by Bookswagon (the "CRR Service").


    By submitting any content to Bookswagon, you guarantee that:
    • You are the sole author and owner of the intellectual property rights in the content;
    • All "moral rights" that you may have in such content have been voluntarily waived by you;
    • All content that you post is accurate;
    • You are at least 13 years old;
    • Use of the content you supply does not violate these Terms of Use and will not cause injury to any person or entity.
    You further agree that you may not submit any content:
    • That is known by you to be false, inaccurate or misleading;
    • That infringes any third party's copyright, patent, trademark, trade secret or other proprietary rights or rights of publicity or privacy;
    • That violates any law, statute, ordinance or regulation (including, but not limited to, those governing, consumer protection, unfair competition, anti-discrimination or false advertising);
    • That is, or may reasonably be considered to be, defamatory, libelous, hateful, racially or religiously biased or offensive, unlawfully threatening or unlawfully harassing to any individual, partnership or corporation;
    • For which you were compensated or granted any consideration by any unapproved third party;
    • That includes any information that references other websites, addresses, email addresses, contact information or phone numbers;
    • That contains any computer viruses, worms or other potentially damaging computer programs or files.
    You agree to indemnify and hold Bookswagon (and its officers, directors, agents, subsidiaries, joint ventures, employees and third-party service providers, including but not limited to Bazaarvoice, Inc.), harmless from all claims, demands, and damages (actual and consequential) of every kind and nature, known and unknown including reasonable attorneys' fees, arising out of a breach of your representations and warranties set forth above, or your violation of any law or the rights of a third party.


    For any content that you submit, you grant Bookswagon a perpetual, irrevocable, royalty-free, transferable right and license to use, copy, modify, delete in its entirety, adapt, publish, translate, create derivative works from and/or sell, transfer, and/or distribute such content and/or incorporate such content into any form, medium or technology throughout the world without compensation to you. Additionally,  Bookswagon may transfer or share any personal information that you submit with its third-party service providers, including but not limited to Bazaarvoice, Inc. in accordance with  Privacy Policy


    All content that you submit may be used at Bookswagon's sole discretion. Bookswagon reserves the right to change, condense, withhold publication, remove or delete any content on Bookswagon's website that Bookswagon deems, in its sole discretion, to violate the content guidelines or any other provision of these Terms of Use.  Bookswagon does not guarantee that you will have any recourse through Bookswagon to edit or delete any content you have submitted. Ratings and written comments are generally posted within two to four business days. However, Bookswagon reserves the right to remove or to refuse to post any submission to the extent authorized by law. You acknowledge that you, not Bookswagon, are responsible for the contents of your submission. None of the content that you submit shall be subject to any obligation of confidence on the part of Bookswagon, its agents, subsidiaries, affiliates, partners or third party service providers (including but not limited to Bazaarvoice, Inc.)and their respective directors, officers and employees.

    Accept

    New Arrivals

    Inspired by your browsing history


    Your review has been submitted!

    You've already reviewed this product!