Current Signature Analysis for Condition Monitoring of Cage Induction Motors
Home > Science, Technology & Agriculture > Electronics and communications engineering > Current Signature Analysis for Condition Monitoring of Cage Induction Motors: Industrial Application and Case Histories
Current Signature Analysis for Condition Monitoring of Cage Induction Motors: Industrial Application and Case Histories

Current Signature Analysis for Condition Monitoring of Cage Induction Motors: Industrial Application and Case Histories

|
     0     
5
4
3
2
1




International Edition


About the Book

Provides coverage of Motor Current Signature Analysis (MCSA) for cage induction motors This book is primarily for industrial engineers. It has 13 chapters and contains a unique data base of 50 industrial case histories on the application of MCSA to diagnose broken rotor bars or unacceptable levels of airgap eccentricity in cage induction motors with ratings from 127 kW (170 H.P.) up to 10,160 kW (13,620 H.P.). There are also unsuccessful case histories, which is another unique feature of the book. The case studies also illustrate the effects of mechanical load dynamics downstream of the motor on the interpretation of current signatures. A number of cases are presented where abnormal operation of the driven load was diagnosed. Chapter 13 presents a critical appraisal of MCSA including successes, failures and lessons learned via industrial case histories.  The case histories are presented in a step by step format, with predictions and outcomes supported by current spectra and photographic evidence to confirm a correct or incorrect diagnosis The case histories are presented in detail so readers fully understand the diagnosis The authors have 108 years of combined experience in the installation, maintenance, repair, design, manufacture, operation and condition monitoring of SCIMs There are 10 questions at the end of chapters 1 to 12 and answers can be obtained via the publisher Current Signature Analysis for Condition Monitoring of Cage Induction Motors serves as a reference for professional engineers, head electricians and technicians working with induction motors.  To obtain the solutions manual for this book, please send an email to pressbooks@ieee.org. William T. Thomson is Director and Consultant with EM Diagnostics Ltd, in Scotland. Prof. Thomson received a BSc (Hons) in Electrical Engineering in 1973 and an MSc in 1977 from the University of Strathclyde. He has published 72 papers on condition monitoring of induction motors in a variety of engineering journals such as IEEE Transactions (USA), IEE Proceedings (UK), and also at numerous International IEEE and IEE conferences. He is a senior member of the IEEE, a fellow of the IEE (IET) in the UK and a Chartered Professional Engineer registered in the UK. Ian Culbert was a Rotating Machines Specialist at Iris Power Qualitrol since April 2002 until his very untimely death on 8th September, 2015. At this company he provided consulting services to customers, assisted in product development, trained sales and field service staff and reviewed stator winding partial discharge reports. He has co-authored two books on electrical machine insulation design, evaluation, aging, testing and repair and was principal author of a number of Electric Power Research Institute reports on motor repair. Ian was a Registered Professional Engineer in the Province of Ontario, Canada and a Senior Member of IEEE.

Table of Contents:
ABOUT THE AUTHORS xiii OBITUARY TO IAN CULBERT xv ACKNOWLEDGMENTS xvii FOREWORD xix PREFACE xxiii NOMENCLATURE xxvii ACRONYMS AND ABBREVIATIONS xxxiii RELEVANT UNITS OF EQUIVALENCE USEFUL FOR THIS BOOK xxxv CHAPTER 1 MOTOR CURRENT SIGNATURE ANALYSIS FOR INDUCTION MOTORS 1 1.0 Introduction 1 1.1 Historical Development of MCSA and Goals of This Book 4 1.2 Basic Theory of Operation of the 3-Phase Induction Motor 6 1.3 Starting and Run-Up Characteristics of SCIMs 20 1.4 Illustrations of Construction of a Large HV SCIM 29 1.5 Questions 33 References 34 CHAPTER 2 DESIGN, CONSTRUCTION, AND MANUFACTURE OF SQUIRREL CAGE ROTORS 39 2.0 Introduction 39 2.1 Aluminum and Copper Die-Cast Windings 40 2.2 Fabricated Squirrel Cage Windings 43 2.3 Design and Manufacturing Features of Squirrel Cage Rotor Windings to Minimize Failures 52 2.4 Questions 53 References 54 CHAPTER 3 CAUSES OF BREAKS IN SQUIRREL CAGE WINDINGS DURING DIRECT-ON-LINE STARTS AND STEADY-STATE OPERATION 55 3.0 Introduction 55 3.1 Mechanical Stresses and Consequential Forces on Rotor Bars and End Rings 56 3.2 Thermal Stresses in the Rotor Bars and End Rings 57 3.3 Broken Bars and End Rings Due to Combined Mechanical and Thermal Stresses When Starting High Inertia Loads 59 3.4 Rotor Bar Stresses Resulting from a Loose Slot Fit 60 3.5 Strengths and Weaknesses of Certain Bar and End Ring Shapes and Types of Joints 62 3.6 Pulsating Loads Due to Crushers and Compressors 62 3.7 Direct-On-Line Starting of Large Induction Motors Driving High Inertia Fans 63 3.8 Direct-On-Line Starting of Large Induction Motors Driving Centrifugal Pumps 66 3.9 Limitations on Repetitive Motor Starts 68 3.10 Criteria for Design of Squirrel Cage Rotor Windings 69 3.11 Samples of Breaks in Squirrel Cage Rotor Windings 72 3.12 Questions 77 References 77 Further Reading 78 CHAPTER 4 MOTOR CURRENT SIGNATURE ANALYSIS (MCSA) TO DETECT CAGE WINDING DEFECTS 79 4.0 Summary 79 4.1 Introduction 79 4.2 Derivation of Current Component at f (1 − 2s) 82 4.3 Reasons for Current Component at f (1 + 2s) 83 4.4 Spectrum Analysis of Current 85 4.5 Severity Indicators for Assessing Condition of Cage Windings at Full-Load 93 4.6 The dB Broken Bar Severity Chart 110 4.7 Influence of Number of Rotor Bars and Pole Number on the Equivalent Broken Bar Factor with Measured dB Difference Values 111 4.8 Questions 116 References 118 CHAPTER 5 MCSA INDUSTRIAL CASE HISTORIES—DIAGNOSIS OF CAGE WINDING DEFECTS IN SCIMs DRIVING STEADY LOADS 119 5.0 Introduction and Summary of Case Histories 119 5.1 Case History (2000–2014)—Summary and Key Features 120 5.2 Case History (1983)—Summary and Key Features 122 5.3 Case History (1982)—Summary and Key Features 125 5.4 Case History (2002)—Summary and Key Features 128 5.5 Case History (1985–1987)—Summary and Key Features 133 5.6 Case History (2006)—Summary and Key Features 136 5.7 MCSA Case History (2004)—Summary and Key Features 139 5.8 MCSA Case History (2004)—Summary and Key Features 141 5.9 Questions 143 References 144 CHAPTER 6 MCSA CASE HISTORIES—DIAGNOSIS OF CAGE WINDING DEFECTS IN SCIMs FITTED WITH END RING RETAINING RINGS 147 6.0 Introduction and Summary of Case Histories 147 6.1 Case History (2006)—Summary 148 6.2 Concluding Remarks on this Challenging Case History 160 6.3 Case History (1990)—Summary and Key Features 161 6.4 Summary and Lessons Learned from Industrial Case Histories in Chapters 5 and 6 166 6.5 Questions 170 References 172 CHAPTER 7 MCSA CASE HISTORIES—CYCLIC LOADS CAN CAUSE FALSE POSITIVES OF CAGE WINDING BREAKS 173 7.1 Introduction and Summary of Case Histories 173 7.2 Case History (2006)—Effect of Gas Recycling in a Centrifugal Gas Compressor and the Detection of Broken Rotor Bars 179 7.3 Case History: False Positive of Broken Rotor Bars Due to Recycling of Gas in a Centrifugal Compressor 180 7.4 Two Case Histories (2002 and 2013)—Broken Rotor Bars in the Same SCIM without and with Gas Recycling in a Gas Compressor 185 7.5 Case History 1986–Fluid Coupling Dynamics Caused a False Positive of a Cage Winding Break 193 7.6 Questions 198 References 200 CHAPTER 8 MCSA CASE HISTORIES—SCIM DRIVES WITH SLOW SPEED GEARBOXES AND FLUCTUATING LOADS CAN GIVE FALSE POSITIVES OF BROKEN ROTOR BARS 201 8.1 Introduction and Summary of Case Histories 201 8.2 Case History (1989)—Slow Speed Coal Conveyor, Load Fluctuations, and Gearbox in the Drive Train 213 8.3 MCSA Case History (1990)—Possible False Positive of Broken Rotor Bars in a SCIM Driving a Coal Conveyor Via a Slow Speed Gearbox 216 8.4 Case History (1992)—Impossible to Analyze MCSA Data Due to Severe Random Current Fluctuations from The Mechanical Load Dynamics from the Coal Crusher 217 8.5 Case History (1995)—Successful Assessment of Cage Windings When the Load Current Fluctuations are Normal from a SCIM Driving Coal Crusher 221 8.6 Two Case Histories (2015)—False Positive of Broken Bars in One of the SCIMs Driving Thrusters on an FPSO If Influence of Drive Dynamics is Discounted 227 8.7 Questions 237 References 238 CHAPTER 9 MISCELLANEOUS MCSA CASE HISTORIES 241 9.0 Introduction and Summary of Case Histories 241 9.1 Possible False Positives of Cage Winding Breaks in Two 1850 kW SCIMs, Due to Number of Poles (2p) Equal to Number of Spider Support Arms (Sp) on Shaft (1991) 242 9.2 Case History (2007)—SCIM with Number of Poles Equal to Number of Kidney Shaped Axial Ducts in the Rotor—False Positive of Broken Bars Prevented by Load Changes 251 9.3 Two Case Histories (2005–2008)—Normal and Abnormal Pumping Dynamics in Two SCIM Seawater Lift Pump Drive Trains 253 9.4 MCSA Case History (2006–2007)—Slack and Worn Belt Drives in Two SCIM Cooling Fan Drives in a Cement Factory 259 9.5 Application of MCSA to Inverter-FED LV and HV SCIMs 263 9.6 Case History (1990)—Assessment of the Mechanical Operational Condition of an Electrical Submersible Pump (ESP) Driven by a SCIM Used in Artificial Oil Lift 267 9.7 Questions 270 References 271 CHAPTER 10 MCSA TO ESTIMATE THE OPERATIONAL AIRGAP ECCENTRICITY IN SQUIRREL CAGE INDUCTION MOTORS 273 10.0 Summary and Introduction 273 10.1 Definition of Airgap Eccentricity 274 10.2 Causes and Associated Types of Airgap Eccentricity 276 10.3 Unbalanced Magnetic Pull (UMP) and Rotor Pull-Over 281 10.4 Current Signature Pattern due to Airgap Eccentricity 284 10.5 Questions 294 References 295 CHAPTER 11 CASE HISTORIES—SUCCESSFUL AND UNSUCCESSFUL APPLICATION OF MCSA TO ESTIMATE OPERATIONAL AIRGAP ECCENTRICITY IN SCIMS 299 11.0 Summary and List of Case Histories 299 11.1 Flow Chart of MCSA Procedure to Estimate Operational Airgap Eccentricity 300 11.2 Case History (1989)—Low Level of Airgap Eccentricity in a SCIM Driving a Centrifugal Air Compressor 302 11.3 Two Case Histories (2004)—Operational Airgap Eccentricity in Nominally Identical SCIMs Driving Pumps in a CCGT Power Station 307 11.4 Four Case Histories (2005)—Abnormal Level of Airgap Eccentricity in a Large, Low Speed, HV Motor Driving a Cooling Water Pump in a Power Station 310 11.5 Case History (1988)—High Level of Airgap Eccentricity in an HV SCIM Driving a Pump in a Large Oil Storage Tank Facility 318 11.6 Case History (2001)—High Airgap Eccentricity in a Cooling Water Pump Motor that Caused Severe Mechanical Damage to HV Stator Coils 324 11.7 Case History (2008)—Unsuccessful Application of MCSA Applied to a Large (6300 kW), Inverter-FED, 6600 V SCIM During a No-Load Run to Assess Its Operational Airgap Eccentricity 332 11.8 Case History (2008)—Successful Application of MCSA Applied to a Large (4500 kW), Inverter-Fed, 3300 V SCIM to Assess its Operational Airgap Eccentricity 335 11.9 Case History (2007)—Advanced MCSA Interpretation of Current Spectra Was Required to Verify High Airgap Eccentricity in an HV SCIM Driving a Primary Air (PA) Fan in a Power Station 339 11.10 Case History (1990)—Unsuccessful MCSA Case History to Assess Operational Airgap Eccentricity in an HV SCIM Driving a Slow Speed Reciprocating Compressor 343 11.11 Case History (2002)—Predict Number of Rotor Slots and Assessment of Operational Airgap Eccentricity in a Large 6600 V, 6714 kW/9000 HP SCIM Driving a Centrifugal Compressor 347 11.12 Questions 353 References 357 CHAPTER 12 CRITICAL APPRAISAL OF MCSA TO DIAGNOSE SHORT CIRCUITED TURNS IN LV AND HV STATOR WINDINGS AND FAULTS IN ROLLER ELEMENT BEARINGS IN SCIMS 359 12.1 Summary 359 12.2 Shorted Turns in HV Stator Winding Coils 361 12.3 Detection of Shorted Turns Via MCSA under Controlled Experimental Conditions 364 12.4 Detection of Defects in Roller Element Bearings Via MCSA 368 12.5 Questions 371 References 372 CHAPTER 13 APPRAISAL OF MCSA INCLUDING LESSONS LEARNED VIA INDUSTRIAL CASE HISTORIES 375 13.1 Summary of MCSA in Industry to Diagnose Cage Winding Breaks 375 13.2 Flow Chart for Measurement and Analysis of Current to Diagnose Cage Winding Breaks 375 13.3 MCSA to Diagnose Broken Rotor Bars in SCIMs Driving Steady Loads 379 13.4 Number of Rotor Bars, External Constraints, and Lessons Learned 380 13.5 Effect of End Ring Retaining Rings (ERRS) on Diagnosis of Broken Rotor Bars 381 13.6 MCSA Applied to SCIMs Driving Complex Mechanical Plant, Lessons Learned, and Recommendations 382 13.7 Double Cage Rotors—Classical MCSA can only Detect Cage Winding Breaks in Inner Run Winding 382 13.8 MCSA to Diagnose Operational Levels of Airgap Eccentricity in SCIMs 383 13.9 Recommendations to End Users 385 13.10 Suggested Research and Development Projects 386 References 388 Appendix 13.A Commentary on Interpretation of LV and HV Used in SCIMs 388 LIST OF EQUATIONS 389 INDEX 393


Best Sellers


Product Details
  • ISBN-13: 9781119029595
  • Publisher: John Wiley & Sons Inc
  • Binding: Hardback
  • Language: English
  • Returnable: N
  • Spine Width: 28 mm
  • Weight: 797 gr
  • ISBN-10: 1119029597
  • Publisher Date: 08 Dec 2017
  • Height: 239 mm
  • No of Pages: 448
  • Returnable: N
  • Sub Title: Industrial Application and Case Histories
  • Width: 155 mm


Similar Products

Add Photo
Add Photo

Customer Reviews

REVIEWS      0     
Click Here To Be The First to Review this Product
Current Signature Analysis for Condition Monitoring of Cage Induction Motors: Industrial Application and Case Histories
John Wiley & Sons Inc -
Current Signature Analysis for Condition Monitoring of Cage Induction Motors: Industrial Application and Case Histories
Writing guidlines
We want to publish your review, so please:
  • keep your review on the product. Review's that defame author's character will be rejected.
  • Keep your review focused on the product.
  • Avoid writing about customer service. contact us instead if you have issue requiring immediate attention.
  • Refrain from mentioning competitors or the specific price you paid for the product.
  • Do not include any personally identifiable information, such as full names.

Current Signature Analysis for Condition Monitoring of Cage Induction Motors: Industrial Application and Case Histories

Required fields are marked with *

Review Title*
Review
    Add Photo Add up to 6 photos
    Would you recommend this product to a friend?
    Tag this Book Read more
    Does your review contain spoilers?
    What type of reader best describes you?
    I agree to the terms & conditions
    You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.

    CUSTOMER RATINGS AND REVIEWS AND QUESTIONS AND ANSWERS TERMS OF USE

    These Terms of Use govern your conduct associated with the Customer Ratings and Reviews and/or Questions and Answers service offered by Bookswagon (the "CRR Service").


    By submitting any content to Bookswagon, you guarantee that:
    • You are the sole author and owner of the intellectual property rights in the content;
    • All "moral rights" that you may have in such content have been voluntarily waived by you;
    • All content that you post is accurate;
    • You are at least 13 years old;
    • Use of the content you supply does not violate these Terms of Use and will not cause injury to any person or entity.
    You further agree that you may not submit any content:
    • That is known by you to be false, inaccurate or misleading;
    • That infringes any third party's copyright, patent, trademark, trade secret or other proprietary rights or rights of publicity or privacy;
    • That violates any law, statute, ordinance or regulation (including, but not limited to, those governing, consumer protection, unfair competition, anti-discrimination or false advertising);
    • That is, or may reasonably be considered to be, defamatory, libelous, hateful, racially or religiously biased or offensive, unlawfully threatening or unlawfully harassing to any individual, partnership or corporation;
    • For which you were compensated or granted any consideration by any unapproved third party;
    • That includes any information that references other websites, addresses, email addresses, contact information or phone numbers;
    • That contains any computer viruses, worms or other potentially damaging computer programs or files.
    You agree to indemnify and hold Bookswagon (and its officers, directors, agents, subsidiaries, joint ventures, employees and third-party service providers, including but not limited to Bazaarvoice, Inc.), harmless from all claims, demands, and damages (actual and consequential) of every kind and nature, known and unknown including reasonable attorneys' fees, arising out of a breach of your representations and warranties set forth above, or your violation of any law or the rights of a third party.


    For any content that you submit, you grant Bookswagon a perpetual, irrevocable, royalty-free, transferable right and license to use, copy, modify, delete in its entirety, adapt, publish, translate, create derivative works from and/or sell, transfer, and/or distribute such content and/or incorporate such content into any form, medium or technology throughout the world without compensation to you. Additionally,  Bookswagon may transfer or share any personal information that you submit with its third-party service providers, including but not limited to Bazaarvoice, Inc. in accordance with  Privacy Policy


    All content that you submit may be used at Bookswagon's sole discretion. Bookswagon reserves the right to change, condense, withhold publication, remove or delete any content on Bookswagon's website that Bookswagon deems, in its sole discretion, to violate the content guidelines or any other provision of these Terms of Use.  Bookswagon does not guarantee that you will have any recourse through Bookswagon to edit or delete any content you have submitted. Ratings and written comments are generally posted within two to four business days. However, Bookswagon reserves the right to remove or to refuse to post any submission to the extent authorized by law. You acknowledge that you, not Bookswagon, are responsible for the contents of your submission. None of the content that you submit shall be subject to any obligation of confidence on the part of Bookswagon, its agents, subsidiaries, affiliates, partners or third party service providers (including but not limited to Bazaarvoice, Inc.)and their respective directors, officers and employees.

    Accept

    New Arrivals

    Inspired by your browsing history


    Your review has been submitted!

    You've already reviewed this product!