Buy The Use of Humidification System to Reduce the Work of Breathing in Mechanical Ventilated Patients
Book 1
Book 2
Book 3
Book 1
Book 2
Book 3
Book 1
Book 2
Book 3
Book 1
Book 2
Book 3
Home > Medicine & Health Science textbooks > Nursing and ancillary services > Nursing > The Use of Humidification System to Reduce the Work of Breathing in Mechanical Ventilated Patients
The Use of Humidification System to Reduce the Work of Breathing in Mechanical Ventilated Patients

The Use of Humidification System to Reduce the Work of Breathing in Mechanical Ventilated Patients


     0     
5
4
3
2
1



Out of Stock


Notify me when this book is in stock
X
About the Book

This dissertation, "The Use of Humidification System to Reduce the Work of Breathing in Mechanical Ventilated Patients" by Wai-ki, Cheung, 張慧琪, was obtained from The University of Hong Kong (Pokfulam, Hong Kong) and is being sold pursuant to Creative Commons: Attribution 3.0 Hong Kong License. The content of this dissertation has not been altered in any way. We have altered the formatting in order to facilitate the ease of printing and reading of the dissertation. All rights not granted by the above license are retained by the author. Abstract: Critically ill patients in an intensive care unit (ICU) often require mechanical ventilation (MV). Humidification systems are essential devices for MV which replace the natural heat and moisture exchange process of inspired gases. A heat and moisture exchanger (HME) is commonly used for the humidification of MV patients in ICU. In contrast, a heated humidifier (HH) that is a more complicated device is used only for prolonged MV patients because of its higher cost and nurse workload. However, HME may increase the breathing workload of patients, thereby inflicting damage to their respiratory function, especially among respiratory failure patients. However, there was no evidence-based guideline that instructs nurses on choosing humidification devices in ICU. This dissertation aimed to 1) evaluate the current evidence and formulate evidence-based guideline in selecting a humidification device for mechanically ventilated acute respiratory distress syndrome (ARDS) patients in reducing the risks of breathing workload; 2) assess its implementation potential, as well as its feasibility and transferability; and 3) develop implementation strategies and evaluation plans for the use of this device in an adult ICU. Three electronic databases, namely, Proquest, Ovid, and Google Scholar, were searched for randomized controlled trials (RCTs) of humidification systems for MV. Eight articles were retrieved. Their reference lists were read and found two additional RCT. Four high-quality RCT showed that HH increased the breathing workload more than HME. Several studies showed that HME has potential drawbacks of significantly increase airway resistance, minute ventilation, CO2 retention, and respiratory discomfort. However, studies showed that no significant difference of ventilator-associated pneumonia (VAP) rate between HME and HH. The initial application of HME is safer and less costlyl. However, prolonged use of HME in ARDS patients may induce further workload on the respiratory system and worsen treatment progress. An evidence-based clinical guideline in choosing the humidification system was formulated and assessed using the appraisal instruments of Scottish Intercollegiate Guideline Network. It is deemed to be transferable with patient characteristics, clinical situation, and organizational infrastructure similar to studies evaluated the suggested innovation. Feasibility was also assessed and is considered to be high. The setup and running cost per year were HKD17450 and HKD6600. Although the humidification system had no actual cost reduction, non-material benefits such as prevention of tube blockage, reduction in breathing workload, and respiratory discomfort were more important than the cost. An implementation plan including a one-month communication plan with stakeholders and one-month pilot testing were developed. The evaluation of the guideline will last for 10 months. The effectiveness of the innovation will be determined by the reduction in breathing workload, cost and benefit ratio, and staff satisfaction level. DOI: 10.5353/th_b5088284 Subjects: Respiratory intensive care Artificial respiration


Best Sellers


Product Details
  • ISBN-13: 9781361004388
  • Publisher: Open Dissertation Press
  • Publisher Imprint: Open Dissertation Press
  • Height: 279 mm
  • No of Pages: 86
  • Weight: 222 gr
  • ISBN-10: 136100438X
  • Publisher Date: 26 Jan 2017
  • Binding: Paperback
  • Language: English
  • Spine Width: 5 mm
  • Width: 216 mm


Similar Products

Add Photo
Add Photo

Customer Reviews

REVIEWS      0     
Click Here To Be The First to Review this Product
The Use of Humidification System to Reduce the Work of Breathing in Mechanical Ventilated Patients
Open Dissertation Press -
The Use of Humidification System to Reduce the Work of Breathing in Mechanical Ventilated Patients
Writing guidlines
We want to publish your review, so please:
  • keep your review on the product. Review's that defame author's character will be rejected.
  • Keep your review focused on the product.
  • Avoid writing about customer service. contact us instead if you have issue requiring immediate attention.
  • Refrain from mentioning competitors or the specific price you paid for the product.
  • Do not include any personally identifiable information, such as full names.

The Use of Humidification System to Reduce the Work of Breathing in Mechanical Ventilated Patients

Required fields are marked with *

Review Title*
Review
    Add Photo Add up to 6 photos
    Would you recommend this product to a friend?
    Tag this Book Read more
    Does your review contain spoilers?
    What type of reader best describes you?
    I agree to the terms & conditions
    You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.

    CUSTOMER RATINGS AND REVIEWS AND QUESTIONS AND ANSWERS TERMS OF USE

    These Terms of Use govern your conduct associated with the Customer Ratings and Reviews and/or Questions and Answers service offered by Bookswagon (the "CRR Service").


    By submitting any content to Bookswagon, you guarantee that:
    • You are the sole author and owner of the intellectual property rights in the content;
    • All "moral rights" that you may have in such content have been voluntarily waived by you;
    • All content that you post is accurate;
    • You are at least 13 years old;
    • Use of the content you supply does not violate these Terms of Use and will not cause injury to any person or entity.
    You further agree that you may not submit any content:
    • That is known by you to be false, inaccurate or misleading;
    • That infringes any third party's copyright, patent, trademark, trade secret or other proprietary rights or rights of publicity or privacy;
    • That violates any law, statute, ordinance or regulation (including, but not limited to, those governing, consumer protection, unfair competition, anti-discrimination or false advertising);
    • That is, or may reasonably be considered to be, defamatory, libelous, hateful, racially or religiously biased or offensive, unlawfully threatening or unlawfully harassing to any individual, partnership or corporation;
    • For which you were compensated or granted any consideration by any unapproved third party;
    • That includes any information that references other websites, addresses, email addresses, contact information or phone numbers;
    • That contains any computer viruses, worms or other potentially damaging computer programs or files.
    You agree to indemnify and hold Bookswagon (and its officers, directors, agents, subsidiaries, joint ventures, employees and third-party service providers, including but not limited to Bazaarvoice, Inc.), harmless from all claims, demands, and damages (actual and consequential) of every kind and nature, known and unknown including reasonable attorneys' fees, arising out of a breach of your representations and warranties set forth above, or your violation of any law or the rights of a third party.


    For any content that you submit, you grant Bookswagon a perpetual, irrevocable, royalty-free, transferable right and license to use, copy, modify, delete in its entirety, adapt, publish, translate, create derivative works from and/or sell, transfer, and/or distribute such content and/or incorporate such content into any form, medium or technology throughout the world without compensation to you. Additionally,  Bookswagon may transfer or share any personal information that you submit with its third-party service providers, including but not limited to Bazaarvoice, Inc. in accordance with  Privacy Policy


    All content that you submit may be used at Bookswagon's sole discretion. Bookswagon reserves the right to change, condense, withhold publication, remove or delete any content on Bookswagon's website that Bookswagon deems, in its sole discretion, to violate the content guidelines or any other provision of these Terms of Use.  Bookswagon does not guarantee that you will have any recourse through Bookswagon to edit or delete any content you have submitted. Ratings and written comments are generally posted within two to four business days. However, Bookswagon reserves the right to remove or to refuse to post any submission to the extent authorized by law. You acknowledge that you, not Bookswagon, are responsible for the contents of your submission. None of the content that you submit shall be subject to any obligation of confidence on the part of Bookswagon, its agents, subsidiaries, affiliates, partners or third party service providers (including but not limited to Bazaarvoice, Inc.)and their respective directors, officers and employees.

    Accept

    Fresh on the Shelf


    Inspired by your browsing history


    Your review has been submitted!

    You've already reviewed this product!