Buy ARC Flash Hazard Analysis and Mitigation - Bookswagon
Book 1
Book 2
Book 3
Book 1
Book 2
Book 3
Book 1
Book 2
Book 3
Book 1
Book 2
Book 3
Home > Science, Technology & Agriculture > Energy technology and engineering > ARC Flash Hazard Analysis and Mitigation: (91 IEEE Press Series on Power Engineering)
ARC Flash Hazard Analysis and Mitigation: (91 IEEE Press Series on Power Engineering)

ARC Flash Hazard Analysis and Mitigation: (91 IEEE Press Series on Power Engineering)


     0     
5
4
3
2
1



Out of Stock


Notify me when this book is in stock
X
About the Book

Up-to-date analysis methodologies and practical mitigation for a major electrical safety concern Arc Flash Hazard Analysis and Mitigation is the first book to focus specifically on arc flash hazards and provide the latest methodologies for its analysis as well as practical mitigation techniques. Consisting of sixteen chapters, this fully up-to-date handbook covers all aspects of arc flash hazard calculations and mitigation. It addresses the calculations of short circuits, protective relaying, and varied electrical systems configurations in electrical power systems. It also examines protection systems, including differential relays, arc flash sensing relays, protective relaying coordination, current transformer operation and saturation, and applications to major electrical equipment from the arc flash point of view. Current technologies and strategies for arc flash mitigation are explored. Using the methodology, analysis, and preventive measures discussed in the book, the arc flash hazard incident energy can be reduced to 8 cal/cm2 or less for the new and existing electrical distribution systems. This powerful resource: Features the most up-to-date arc flash analysis methodologies Presents arc flash hazard calculations in dc systems Supplies practical examples and case studies Provides end-of-chapter reviews and questions Includes a Foreword written by Lanny Floyd, a world-renowned leader in electrical safety who is DuPont's Principal Consultant on Electrical Safety and Technology Arc Flash Hazard Analysis and Mitigation is a must-have guide for electrical engineers engaged in design, operation, and maintenance, consulting engineers, facility managers, and safety professionals.

Table of Contents:
Foreword xix Preface xxi About the Author xxiii 1 ARC FLASH HAZARDS AND THEIR ANALYSES 1 1.1 Electrical Arcs 2 1.2 Arc Flash Hazard and Personal Safety 4 1.3 Time Motion Studies 5 1.4 Arc Flash Hazards 6 1.5 Arc Blast 6 1.6 Electrical Shock Hazard 9 1.7 Fire Hazard 14 1.8 Arc Flash Hazard Analysis 15 1.9 Personal Protective Equipment 23 1.10 Hazard Boundaries 24 1.11 Maximum Duration of an Arc Flash Event and Arc Flash Boundary 26 1.12 Reasons for Internal Arcing Faults 29 1.13 Arc Flash Hazard Calculation Steps 30 1.14 Examples of Calculations 32 1.15 Reducing Arc Flash Hazard 36 2 SAFETY AND PREVENTION THROUGH DESIGN: A NEW FRONTIER 40 2.1 Electrical Standards and Codes 41 2.2 Prevention through Design 43 2.3 Limitations of Existing Codes, Regulations, and Standards 44 2.4 Electrical Hazards 45 2.5 Changing the Safety Culture 48 2.6 Risk Analysis for Critical Operation Power Systems 48 2.7 Reliability Analysis 50 2.8 Maintenance and Operation 53 2.9 Safety Integrity Level and Safety Instrumented System 55 3 CRITIQUE OF IEEE GUIDE 1584 ARC FLASH CALCULATIONS 60 3.1 Variations of Arcing Currents 60 3.2 Gap between Electrodes 62 3.3 Variations of Incident Energy 64 3.4 Some Anomalies in IEEE Equations 64 3.5 Lee's Arc Model 66 3.6 IEEE Experimental Model Setup 68 3.7 Electrical Arc Burn Hazard 70 3.8 Effect of Insulating Barriers 72 3.9 Arc Flash Test Models 76 3.10 Alternate Equations 77 3.11 Further Testing and Research 78 3.12 Effectiveness of PPE Calculated Based on IEEE 1584 Guide 79 4 ARC FLASH HAZARD AND SYSTEM GROUNDING 82 4.1 System and Equipment Grounding 82 4.2 Low Resistance Grounding 87 4.3 High Resistance Grounded Systems 87 4.4 Ungrounded Systems 94 4.5 Reactance Grounding 95 4.6 Resonant Grounding 95 4.7 Corner of Delta-Grounded Systems 95 4.8 Surge Arresters 96 4.9 Artifi cially Derived Neutrals 97 4.10 Multiple Grounded Systems 100 4.11 Arc Flash Hazard in Solidly Grounded Systems 100 4.12 Protection and Coordination in Solidly Grounded Systems 105 4.13 Ground Fault Coordination in Low Resistance Grounded Medium Voltage Systems 114 4.14 Monitoring of Grounding Resistors 123 4.15 Selection of Grounding Systems 124 5 SHORT-CIRCUIT CALCULATIONS ACCORDING TO ANSI/IEEE STANDARDS FOR ARC FLASH ANALYSIS 128 5.1 Types of Calculations 129 5.2 Rating Structure of HV Circuit Breakers 130 5.3 Low-Voltage Motors 133 5.4 Rotating Machine Model 134 5.5 Calculation Methods 134 5.6 Network Reduction 138 5.7 Calculation Procedure 138 5.8 Capacitor and Static Converter Contributions to Short-Circuit Currents 141 5.9 Typical Computer-Based Calculation Results 141 5.10 Examples of Calculations 144 5.11 Thirty-Cycle Short-Circuit Currents 159 5.12 Unsymmetrical Short-Circuit Currents 160 5.13 Computer Methods 169 6 ACCOUNTING FOR DECAYING SHORT-CIRCUIT CURRENTS IN ARC FLASH CALCULATIONS 176 6.1 Short Circuit of a Passive Element 176 6.2 Systems with No AC Decay 179 6.3 Reactances of a Synchronous Machine 180 6.4 Saturation of Reactances 182 6.5 Time Constants of Synchronous Machines 182 6.6 Synchronous Machine Behavior on Terminal Short Circuit 183 6.7 Short Circuit of Synchronous Motors and Condensers 192 6.8 Short Circuit of Induction Motors 192 6.9 A New Algorithm for Arc Flash Calculations with Decaying Short-Circuit Currents 195 7 PROTECTIVE RELAYING 203 7.1 Protection and Coordination from Arc Flash Considerations 203 7.2 Classifi cation of Relay Types 207 7.3 Design Criteria of Protective Systems 207 7.4 Overcurrent Protection 209 7.5 Low Voltage Circuit Breakers 216 7.6 Short-Circuit Ratings of Low Voltage Circuit Breakers 228 7.7 Series-Connected Ratings 233 7.8 Fuses 234 7.9 Application of Fuses for Arc Flash Reduction 239 7.10 Conductor Protection 244 7.11 Motor Protection 250 7.12 Generator 51-V Protection 259 8 UNIT PROTECTION SYSTEMS 266 8.1 Overlapping the Zones of Protection 268 8.2 Importance of Differential Systems for Arc Flash Reduction 270 8.3 Bus Differential Schemes 272 8.4 High Impedance Differential Relays 276 8.5 Low Impedance Current Differential Relays 280 8.6 Electromechanical Transformer Differential Relays 285 8.7 Microprocessor-Based Transformer Differential Relays 288 8.8 Pilot Wire Protection 295 8.9 Modern Line Current Differential Protection 296 8.10 Examples of Arc Flash Reduction with Differential Relays 301 9 ARC FAULT DETECTION RELAYS 306 9.1 Principle of Operation 307 9.2 Light Intensity 307 9.3 Light Sensor Types 308 9.4 Other Hardware 313 9.5 Selective Tripping 314 9.6 Supervision with Current Elements 316 9.7 Applications 316 9.8 Examples of Calculation 318 9.9 Arc Vault Protection for Low Voltage Systems 318 10 OVERCURRENT COORDINATION 326 10.1 Standards and Requirements 327 10.2 Data for the Coordination Study 327 10.3 Computer-Based Coordination 329 10.4 Initial Analysis 329 10.5 Coordinating Time Interval 330 10.6 Fundamental Considerations for Coordination 330 10.7 Coordination on Instantaneous Basis 332 10.8 NEC Requirements of Selectivity 343 10.9 Energy Boundary Curves 346 10.10 The Art of Compromise 353 11 TRANSFORMER PROTECTION 365 11.1 NEC Requirements 365 11.2 Arc Flash Considerations 367 11.3 System Confi gurations of Transformer Connections 368 11.4 Through Fault Current Withstand Capability 373 11.5 Constructing the Through Fault Curve Analytically 381 11.6 Transformer Primary Fuse Protection 382 11.7 Overcurrent Relays for Transformer Primary Protection 384 11.8 Listing Requirements 386 11.9 Effect of Transformer Winding Connections 390 11.10 Requirements of Ground Fault Protection 392 11.11 Through Fault Protection 392 11.12 Overall Transformer Protection 394 11.13 A Practical Study for Arc Flash Reduction 395 12 CURRENT TRANSFORMERS 413 12.1 Accuracy Classification of CTs 414 12.2 Constructional Features of CTs 416 12.3 Secondary Terminal Voltage Rating 418 12.4 CT Ratio and Phase Angle Errors 419 12.5 Interrelation of CT Ratio and C Class Accuracy 422 12.6 Polarity of Instrument Transformers 424 12.7 Application Considerations 425 12.8 Series and Parallel Connections of CTs 432 12.9 Transient Performance of the CTs 432 12.10 Practicality of Application 435 12.11 CTs for Low Resistance-Grounded Medium Voltage Systems 437 12.12 Future Directions 437 13 ARC-RESISTANT EQUIPMENT 442 13.1 Calculations of Arc Flash Hazard in Arc-Resistant Equipment 443 13.2 Qualifi cations in IEEE Guide 444 13.3 Accessibility Types 445 13.4 IEC Accessibility Types 446 13.5 Arc-Resistant Ratings 447 13.6 Testing According to IEEE Guide 451 13.7 Pressure Relief 453 13.8 Venting and Plenums 455 13.9 Cable Entries 457 14 RECENT TRENDS AND INNOVATIONS 461 14.1 Statistical Data of Arc Flash Hazards 461 14.2 Zone-Selective Interlocking 463 14.3 Microprocessor-Based Low Voltage Switchgear 473 14.4 Low Voltage Motor Control Centers 477 14.5 Maintenance Mode Switch 485 14.6 Infrared Windows and Sight Glasses 487 14.7 Fault Current Limiters 490 14.8 Partial Discharge Measurements 494 15 ARC FLASH HAZARD CALCULATIONS IN DC SYSTEMS 503 15.1 Calculations of the Short-Circuit Currents in DC Systems 504 15.2 Sources of DC Short-Circuit Currents 504 15.3 IEC Calculation Procedures 505 15.4 Short Circuit of a Lead Acid Battery 508 15.5 Short Circuit of DC Motors and Generators 512 15.6 Short-Circuit Current of a Rectifier 517 15.7 Short Circuit of a Charged Capacitor 522 15.8 Total Short-Circuit Current 523 15.9 DC Circuit Breakers and Fuses 524 15.10 Arcing in DC Systems 527 15.11 Equations for Calculation of Incident Energy in DC Systems 532 15.12 Protection of the Semiconductor Devices 534 16 APPLICATION OF ETHERNET AND IEC 61850 COMMUNICATIONS 540 16.1 IEC 61850 Protocol 541 16.2 Modern IEDs 542 16.3 Substation Architecture 543 16.4 IEC 61850 Communication Structure 544 16.5 Logical Nodes 546 16.6 Ethernet Connection 546 16.7 Networking Media 550 16.8 Network Topologies 552 16.9 Application to Arc Flash Relaying and Communications 556 Review Questions 556 References 556 Appendix A Statistics and Probability Applied to Electrical Engineering 558 A.1 Mean Mode and Median 558 A.2 Mean and Standard Deviation 559 A.3 Skewness and Kurtosis 560 A.4 Normal or Gaussian Distribution 561 A.5 Curve Fitting: Least Square Line 563 References 566 Appendix B Tables for Quick Estimation of Incident Energy and PPE in Electrical Systems 567 Index 605

About the Author :
J. C. Das is a Staff Consultant on Electrical Power Systems with AMEC Inc., in Tucker, Georgia. He is Life Fellow of IEEE (UK), Fellow of IET (India), and has authored approximately sixty technical papers and published 190 study reports of real-world power systems. He is the author of two other books, Power System Analysis: Short-Circuit Load Flow and Harmonics, Second Edition, and Transients in Electrical Systems: Analysis, Recognition, and Mitigation. He is a registered P.E. in the states of Georgia and Oklahoma, C.Eng. in UK, and Eur Ing in Europe. J. C. Das is also a member of CIGRE, Federation of European Engineers, and other technical associations and organizations.

Review :
“If you need to perform arc flash hazard calculations, then this book will not only give you the equations and background necessary to obtain the correct classification, but it will also provide an understanding of how these equations were derived and their limitations.”  (IEEE Electrical Insulation Magazine, 1 March 2013)


Best Sellers


Product Details
  • ISBN-13: 9781118402474
  • Publisher: John Wiley & Sons Inc
  • Publisher Imprint: Wiley-IEEE Press
  • Language: English
  • Series Title: 91 IEEE Press Series on Power Engineering
  • ISBN-10: 1118402472
  • Publisher Date: 15 Aug 2012
  • Binding: Digital (delivered electronically)
  • No of Pages: 644


Similar Products

Add Photo
Add Photo

Customer Reviews

REVIEWS      0     
Click Here To Be The First to Review this Product
ARC Flash Hazard Analysis and Mitigation: (91 IEEE Press Series on Power Engineering)
John Wiley & Sons Inc -
ARC Flash Hazard Analysis and Mitigation: (91 IEEE Press Series on Power Engineering)
Writing guidlines
We want to publish your review, so please:
  • keep your review on the product. Review's that defame author's character will be rejected.
  • Keep your review focused on the product.
  • Avoid writing about customer service. contact us instead if you have issue requiring immediate attention.
  • Refrain from mentioning competitors or the specific price you paid for the product.
  • Do not include any personally identifiable information, such as full names.

ARC Flash Hazard Analysis and Mitigation: (91 IEEE Press Series on Power Engineering)

Required fields are marked with *

Review Title*
Review
    Add Photo Add up to 6 photos
    Would you recommend this product to a friend?
    Tag this Book Read more
    Does your review contain spoilers?
    What type of reader best describes you?
    I agree to the terms & conditions
    You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.

    CUSTOMER RATINGS AND REVIEWS AND QUESTIONS AND ANSWERS TERMS OF USE

    These Terms of Use govern your conduct associated with the Customer Ratings and Reviews and/or Questions and Answers service offered by Bookswagon (the "CRR Service").


    By submitting any content to Bookswagon, you guarantee that:
    • You are the sole author and owner of the intellectual property rights in the content;
    • All "moral rights" that you may have in such content have been voluntarily waived by you;
    • All content that you post is accurate;
    • You are at least 13 years old;
    • Use of the content you supply does not violate these Terms of Use and will not cause injury to any person or entity.
    You further agree that you may not submit any content:
    • That is known by you to be false, inaccurate or misleading;
    • That infringes any third party's copyright, patent, trademark, trade secret or other proprietary rights or rights of publicity or privacy;
    • That violates any law, statute, ordinance or regulation (including, but not limited to, those governing, consumer protection, unfair competition, anti-discrimination or false advertising);
    • That is, or may reasonably be considered to be, defamatory, libelous, hateful, racially or religiously biased or offensive, unlawfully threatening or unlawfully harassing to any individual, partnership or corporation;
    • For which you were compensated or granted any consideration by any unapproved third party;
    • That includes any information that references other websites, addresses, email addresses, contact information or phone numbers;
    • That contains any computer viruses, worms or other potentially damaging computer programs or files.
    You agree to indemnify and hold Bookswagon (and its officers, directors, agents, subsidiaries, joint ventures, employees and third-party service providers, including but not limited to Bazaarvoice, Inc.), harmless from all claims, demands, and damages (actual and consequential) of every kind and nature, known and unknown including reasonable attorneys' fees, arising out of a breach of your representations and warranties set forth above, or your violation of any law or the rights of a third party.


    For any content that you submit, you grant Bookswagon a perpetual, irrevocable, royalty-free, transferable right and license to use, copy, modify, delete in its entirety, adapt, publish, translate, create derivative works from and/or sell, transfer, and/or distribute such content and/or incorporate such content into any form, medium or technology throughout the world without compensation to you. Additionally,  Bookswagon may transfer or share any personal information that you submit with its third-party service providers, including but not limited to Bazaarvoice, Inc. in accordance with  Privacy Policy


    All content that you submit may be used at Bookswagon's sole discretion. Bookswagon reserves the right to change, condense, withhold publication, remove or delete any content on Bookswagon's website that Bookswagon deems, in its sole discretion, to violate the content guidelines or any other provision of these Terms of Use.  Bookswagon does not guarantee that you will have any recourse through Bookswagon to edit or delete any content you have submitted. Ratings and written comments are generally posted within two to four business days. However, Bookswagon reserves the right to remove or to refuse to post any submission to the extent authorized by law. You acknowledge that you, not Bookswagon, are responsible for the contents of your submission. None of the content that you submit shall be subject to any obligation of confidence on the part of Bookswagon, its agents, subsidiaries, affiliates, partners or third party service providers (including but not limited to Bazaarvoice, Inc.)and their respective directors, officers and employees.

    Accept

    Fresh on the Shelf


    Inspired by your browsing history


    Your review has been submitted!

    You've already reviewed this product!